SP Series Portable Power Station
SP Series Portable Power Station 300-1800 W
Parameter | SP0332 | SP0532 | SP1064 | SP18128 | SP0532Y | SP1064Y
MPPT tracking efficiency | 0.99
Max. battery-mode conversion efficiency | 0.87 | 0.95 | 0.92 | 0.87 | 0.95
The SP series belongs to the portable power stations range. Review the exact model in the specification table rather than selecting on the series name alone.
Parameter | SP0332 | SP0532 | SP1064 | SP18128 | SP0532Y | SP1064Y MPPT tracking efficiency | 0.99
Structural Features
Key features of the SP platform:
- Parameter | SP0332 | SP0532 | SP1064 | SP18128 | SP0532Y | SP1064Y
- MPPT tracking efficiency | 0.99
- Max. battery-mode conversion efficiency | 0.87 | 0.95 | 0.92 | 0.87 | 0.95
- Max. PV input power | 300W | 550W | 1200W | 300W | 550W
- Max. PV input voltage | 55V | 60V | 110V | 55V | 60V
Product Advantages
Parameter | SP0332 | SP0532 | SP1064 | SP18128 | SP0532Y | SP1064Y
MPPT tracking efficiency | 0.99
Max. battery-mode conversion efficiency | 0.87 | 0.95 | 0.92 | 0.87 | 0.95
Max. PV input power | 300W | 550W | 1200W | 300W | 550W
Max. PV input voltage | 55V | 60V | 110V | 55V | 60V
For a SP quotation, send the exact model, quantity, destination market, electrical requirements and expected operating duty. Identify any branding, packaging or documentation requirements separately so the supplied configuration is clear.
Technical Parameters
| Parameter | SP0332 | SP0532 | SP1064 | SP18128 | SP0532Y | SP1064Y |
|---|---|---|---|---|---|---|
| Efficiency | ||||||
| MPPT tracking efficiency | 0.99 | |||||
| Max. battery-mode conversion efficiency | 0.87 | 0.95 | 0.92 | 0.87 | 0.95 | |
| PV input | ||||||
| Max. PV input power | 300W | 550W | 1200W | 300W | 550W | |
| Max. PV input voltage | 55V | 60V | 110V | 55V | 60V | |
| MPPT voltage range | 11~55V | 12-60V | 18-110V | 11~55V | 15-60V | |
| Start-up voltage | 11V | 12V | 18V | 11V | 15V | |
| Number of MPPT trackers | 1 | |||||
| Max. PV array power | 300W | 550W | 1200W | 300W | 550W | |
| Max. PV input current | 10A | 15A | 10A | 15A | ||
| Max. input short-circuit current | 20A | |||||
| AC input | ||||||
| Input voltage range | 90~280Vac | 60~145Vac | ||||
| Over-voltage protection (OVP) | 280±10Vac | 145±5Vac | ||||
| Max. AC input power (bypass + battery charge) | 1000W | 1300W | 1500W | 1000W | 1300W | |
| Max. AC input current (bypass + battery charge) | 6A | 10A | 12A | 6A | 10A | |
| Nominal operating frequency | 50Hz | 60Hz | ||||
| AC output | ||||||
| Rated AC output power (inverter mode) | 300W | 500W | 1000W | 1800W | 500W | 1000W |
| Rated AC output voltage (inverter mode) | 230VAC | 120VAC | ||||
| Total voltage harmonic distortion (THD, inverter mode) | <3% | |||||
| Rated AC output current (inverter mode) | 1.3A | 2.2A | 4.3A | 7.8A | 2.2A | 4.3A |
| Rated AC output frequency | 50Hz | 60Hz | ||||
| Transfer time | ≤20ms | |||||
| Surge power | 600VA | 1000VA | 2000VA | 3600VA | 1000VA | 2000VA |
| Overload capacity | CC 3.0 A output @ >300 W; latch output @ <170 VAC | CC 3.0 A output @ >500 W; latch output @ <170 VAC | CC 3.0 A output @ >1000 W; latch output @ <170 VAC | 5min @110%-120% Load; 30s @120%-150% Load; 2s @150%-180% Load; 20ms @>180% Load | CC 3.0 A output @ >500 W; latch output @ <85 VAC | CC 3.0 A output @ >1000 W; latch output @ <85 VAC |
| Battery | ||||||
| Battery type | LiFePO4 | |||||
| Rated battery voltage | 3.2VDC | 6.4VDC | 12.8VDC | 3.2VDC | 6.4VDC | |
| Battery capacity | 314Ah | |||||
| Battery energy | 1004.8Wh | 2009.6Wh | 4019.2Wh | 1004.8Wh | 2009.6Wh | |
| Cycle life | 6000 | |||||
| General data | ||||||
| Operating temperature range | -10 to +60 °C | |||||
| Max. operating altitude | 4000m | |||||
| SOC display | LED | LCD | LED | LCD | ||
| Cooling method | Intelligent fan cooling | |||||
| Noise level | <45 dB(1m) | |||||
| Certification | IEC62619/IEC62368/UN38.3 | |||||
| Mounting | Wall-mount + upright | Upright | Wall-mount + upright | Upright | ||
| Protection | ||||||
| Battery fuse | Yes | |||||
| Overload protection | Yes | |||||
| Short-circuit protection | Yes | |||||
| Over-temperature protection | Yes | |||||
Use the SP electrical limits as the starting point for system design. Confirm the AC supply where applicable, battery voltage, PV string limits and equipment connected to the output. Optional functions must be specified with the order.
Check the battery and charging requirements for the selected SP model. Match permitted charge and discharge current, charging profile and any supported BMS protocol. A matching connector or nominal voltage alone does not confirm compatibility. For a battery-free or DC-only product, use only the interfaces listed in its model table.
For a SP quotation, send the exact model, quantity, destination market, electrical requirements and expected operating duty. Identify any branding, packaging or documentation requirements separately so the supplied configuration is clear.
The table describes one published model revision. Confirm the current supply configuration before ordering.
Before You Order
Use the SP electrical limits as the starting point for system design. Confirm the AC supply where applicable, battery voltage, PV string limits and equipment connected to the output. Optional functions must be specified with the order.
Electrical Match
Check the battery and charging requirements for the selected SP model. Match permitted charge and discharge current, charging profile and any supported BMS protocol. A matching connector or nominal voltage alone does not confirm compatibility. For a battery-free or DC-only product, use only the interfaces listed in its model table.
Installation Plan
Install the SP product within the temperature, ventilation and enclosure conditions stated in its manual. Specify cable sizes, isolation and protection through a qualified installation design. Product dimensions and clearances should be checked before cabinet or mounting work.
Supply Configuration
SP Series — Selection and Application
The SP series belongs to the portable power stations range. Review the exact model in the specification table rather than selecting on the series name alone.
Parameter | SP0332 | SP0532 | SP1064 | SP18128 | SP0532Y | SP1064Y MPPT tracking efficiency | 0.99
Model selection
For SP, first identify the required electrical interface and continuous load.
Parameter | SP0332 | SP0532 | SP1064 | SP18128 | SP0532Y | SP1064Y MPPT tracking efficiency | 0.99
Operating features
Parameter | SP0332 | SP0532 | SP1064 | SP18128 | SP0532Y | SP1064Y
MPPT tracking efficiency | 0.99
Max. battery-mode conversion efficiency | 0.87 | 0.95 | 0.92 | 0.87 | 0.95
Max. PV input power | 300W | 550W | 1200W | 300W | 550W
Max. PV input voltage | 55V | 60V | 110V | 55V | 60V
System integration
Use the SP electrical limits as the starting point for system design. Confirm the AC supply where applicable, battery voltage, PV string limits and equipment connected to the output. Optional functions must be specified with the order.
Battery and charging
Check the battery and charging requirements for the selected SP model. Match permitted charge and discharge current, charging profile and any supported BMS protocol. A matching connector or nominal voltage alone does not confirm compatibility. For a battery-free or DC-only product, use only the interfaces listed in its model table.
Installation planning
Install the SP product within the temperature, ventilation and enclosure conditions stated in its manual. Specify cable sizes, isolation and protection through a qualified installation design. Product dimensions and clearances should be checked before cabinet or mounting work.
Monitoring and interfaces
Check which monitoring ports and communication options are included on the selected SP model. Confirm accessory hardware, protocol and firmware before relying on remote monitoring, battery communication or expansion.
Frequently asked questions
Which SP model should I choose? Start with the model table and the loads or battery system, then confirm the final configuration before ordering.
Are all optional functions included? No. Availability depends on the model, hardware and agreed supply specification.
Can I combine data from different catalogues? Use one matching model and revision. Confirm any differing values with the supplier.
Discuss your requirements
Contact Techfine Group with your SP requirements. Include the model and the application so the electrical configuration and supporting documents can be checked.