MB Series MPPT Controller
MB Series MPPT Solar Charge Controller 20/30 A
Parameter | MB20415F | MB30415F
Rated system voltage | 12/24/36/48 VDC or auto-sensing
Controller operating voltage range | 11-64 V
The MB series belongs to the mppt solar charge controllers range. Review the exact model in the specification table rather than selecting on the series name alone.
Parameter | MB20415F | MB30415F Rated system voltage | 12/24/36/48 VDC or auto-sensing
Structural Features
Key features of the MB platform:
- Parameter | MB20415F | MB30415F
- Rated system voltage | 12/24/36/48 VDC or auto-sensing
- Controller operating voltage range | 11-64 V
- Lead-acid battery types | Maintenance-free (default) / gel / flooded / custom
- Lithium battery types | LiFePO4 / NMC / custom
Product Advantages
Parameter | MB20415F | MB30415F
Rated system voltage | 12/24/36/48 VDC or auto-sensing
Controller operating voltage range | 11-64 V
Lead-acid battery types | Maintenance-free (default) / gel / flooded / custom
Lithium battery types | LiFePO4 / NMC / custom
For a MB quotation, send the exact model, quantity, destination market, electrical requirements and expected operating duty. Identify any branding, packaging or documentation requirements separately so the supplied configuration is clear.
Technical Parameters
| Parameter | MB20415F | MB30415F |
|---|---|---|
| General | ||
| Rated system voltage | 12/24/36/48 VDC or auto-sensing | |
| Controller operating voltage range | 11-64 V | |
| Lead-acid battery types | Maintenance-free (default) / gel / flooded / custom | |
| Lithium battery types | LiFePO4 / NMC / custom | |
| Rated charging current | 20A | 30A |
| Rated charging power | 260 W @12 V | 390 W @12 V |
| Rated charging power | 520 W @24 V | 780 W @24 V |
| Rated charging power | 780 W @36 V | 1170 W @36 V |
| Rated charging power | 1040 W @48 V | 1560 W @48 V |
| Max. PV module open-circuit voltage | 150Vdc | |
| PV input operating voltage range | 18-150 VDC @12 V system | |
| PV input operating voltage range | 36-150 VDC @24 V system | |
| PV input operating voltage range | 48-150 VDC @36 V system | |
| PV input operating voltage range | 64-150 VDC @48 V system | |
| MPPT operating voltage range | 18-110 VDC @12 V system | |
| MPPT operating voltage range | 36-110 VDC @24 V system | |
| MPPT operating voltage range | 48-110 VDC @36 V system | |
| MPPT operating voltage range | 64-110 VDC @48 V system | |
| Tracking efficiency | ≥99.5% | |
| Max. conversion efficiency | 0.975 | |
| Temperature compensation coefficient | -3 mV/°C/2 V | |
| Static loss | 200 mA @12 V; 100 mA @24 V; 50 mA @48 V | |
| DC load output voltage | Same as battery voltage | |
| DC load rated output current | 20A | |
| DC load output control mode | Always-on / always-off mode | |
| Protection functions | PV reverse-polarity, battery reverse-polarity, over-charge/under-charge and over-temperature protection | |
| Cooling method | Fan cooling | |
| Communication | RS485 | |
| LCD backlight time | Default 60 s, backlight mode configurable | |
| Environment | ||
| Operating temperature range | -20 to +50 °C | |
| Storage temperature range | -40 to +70 °C | |
| Relative humidity range | 0-90% RH | |
| Mechanical | ||
| Dimensions | 210×150×80mm | |
| Recommended wiring | 11AWG/4mm² | 9AWG/6mm² |
| Net weight (ref.) | 1.4 | 1.45 |
Use the MB electrical limits as the starting point for system design. Confirm the AC supply where applicable, battery voltage, PV string limits and equipment connected to the output. Optional functions must be specified with the order.
Check the battery and charging requirements for the selected MB model. Match permitted charge and discharge current, charging profile and any supported BMS protocol. A matching connector or nominal voltage alone does not confirm compatibility. For a battery-free or DC-only product, use only the interfaces listed in its model table.
For a MB quotation, send the exact model, quantity, destination market, electrical requirements and expected operating duty. Identify any branding, packaging or documentation requirements separately so the supplied configuration is clear.
The table describes one published model revision. Confirm the current supply configuration before ordering.
Before You Order
Use the MB electrical limits as the starting point for system design. Confirm the AC supply where applicable, battery voltage, PV string limits and equipment connected to the output. Optional functions must be specified with the order.
Electrical Match
Check the battery and charging requirements for the selected MB model. Match permitted charge and discharge current, charging profile and any supported BMS protocol. A matching connector or nominal voltage alone does not confirm compatibility. For a battery-free or DC-only product, use only the interfaces listed in its model table.
Installation Plan
Install the MB product within the temperature, ventilation and enclosure conditions stated in its manual. Specify cable sizes, isolation and protection through a qualified installation design. Product dimensions and clearances should be checked before cabinet or mounting work.
Supply Configuration
MB Series — Selection and Application
The MB series belongs to the mppt solar charge controllers range. Review the exact model in the specification table rather than selecting on the series name alone.
Parameter | MB20415F | MB30415F Rated system voltage | 12/24/36/48 VDC or auto-sensing
Model selection
For MB, first identify the required electrical interface and continuous load.
Parameter | MB20415F | MB30415F Rated system voltage | 12/24/36/48 VDC or auto-sensing
Operating features
Parameter | MB20415F | MB30415F
Rated system voltage | 12/24/36/48 VDC or auto-sensing
Controller operating voltage range | 11-64 V
Lead-acid battery types | Maintenance-free (default) / gel / flooded / custom
Lithium battery types | LiFePO4 / NMC / custom
System integration
Use the MB electrical limits as the starting point for system design. Confirm the AC supply where applicable, battery voltage, PV string limits and equipment connected to the output. Optional functions must be specified with the order.
Battery and charging
Check the battery and charging requirements for the selected MB model. Match permitted charge and discharge current, charging profile and any supported BMS protocol. A matching connector or nominal voltage alone does not confirm compatibility. For a battery-free or DC-only product, use only the interfaces listed in its model table.
Installation planning
Install the MB product within the temperature, ventilation and enclosure conditions stated in its manual. Specify cable sizes, isolation and protection through a qualified installation design. Product dimensions and clearances should be checked before cabinet or mounting work.
Monitoring and interfaces
Check which monitoring ports and communication options are included on the selected MB model. Confirm accessory hardware, protocol and firmware before relying on remote monitoring, battery communication or expansion.
Frequently asked questions
Which MB model should I choose? Start with the model table and the loads or battery system, then confirm the final configuration before ordering.
Are all optional functions included? No. Availability depends on the model, hardware and agreed supply specification.
Can I combine data from different catalogues? Use one matching model and revision. Confirm any differing values with the supplier.
Discuss your requirements
Contact Techfine Group with your MB requirements. Include the model and the application so the electrical configuration and supporting documents can be checked.