LR Series LiFePO4 Battery
LR Series Rack-Mount LiFePO4 Battery 5-11.8 kWh
Parameter | 5120WH | 11776WH
Basic parameters
Cell chemistry | LiFePO4
The LR series belongs to the lifepo4 storage batteries range. Review the exact model in the specification table rather than selecting on the series name alone.
Parameter | 5120WH | 11776WH Basic parameters
Structural Features
Key features of the LR platform:
- Parameter | 5120WH | 11776WH
- Basic parameters
- Cell chemistry | LiFePO4
- Max. continuous discharge current | 100A | 200A
- Rated voltage | 51.2 VDC
Product Advantages
Parameter | 5120WH | 11776WH
Basic parameters
Cell chemistry | LiFePO4
Max. continuous discharge current | 100A | 200A
Rated voltage | 51.2 VDC
For a LR quotation, send the exact model, quantity, destination market, electrical requirements and expected operating duty. Identify any branding, packaging or documentation requirements separately so the supplied configuration is clear.
Technical Parameters
| Parameter | 5120WH | 11776WH |
|---|---|---|
| Basic parameters | ||
| Cell chemistry | LiFePO4 | |
| Max. continuous discharge current | 100A | 200A |
| Rated voltage | 51.2 VDC | |
| Voltage range | 43.2-58.4 VDC | |
| Max. output power | 5120W | 10240W |
| Max. charge voltage | 58.4 V ±0.2 VDC | |
| Recommended charge voltage | 57.6 V ±0.2 VDC | |
| Recommended charge current | 50A | 115A |
| Low power consumption | Self-consumption <=50 mA; sleep mode <=200 uA | |
| Charge current limiting | 10A | 20A |
| Charge/discharge over-current long-delay protection | BMS100: alarm >105 A, protection >110 A/1 s; BMS200: alarm >205 A, protection >210 A/1 s | |
| Discharge over-current instantaneous protection | BMS100:≥150A/100ms BMS200:≥250A/100ms | |
| Over-voltage protection release | Released at discharge >1 A (OVP 59.2 V on 51.2 V units) | |
| Under-voltage protection release | Activated by charger (UVP 43.2 V on 51.2 V units) | |
| Charge over-current protection release | Released at discharge >1 A | |
| Discharge over-current protection release | Released at charge >1 A | |
| Short-circuit protection | Yes, auto-released during charging | |
| MOS over-temperature protection | MOSFET over-temperature protection | |
| Cell temperature protection | Cell low (-20 °C) and high (70 °C) temperature protection | |
| Ambient temperature alarm | Low -20 °C / high 75 °C protection | |
| Cell failure protection | Cell voltage deviation >1 V | |
| Display | LCD display (optionally without LCD) | |
| Depth of discharge (DOD) | ≥95% | |
| Modules connection | 1-15 | |
| Communication | RS232, RS485 and CAN standard | |
| Protection rating | IP21 | |
| Cycle life (standard charge/discharge at room temp.) | >=6000 cycles | |
| Operating temperature range | Discharge: -10 to +50 °C; charge: 0 to +60 °C | |
| Storage temperature | >1 month: 0-35 °C; <=1 month: -20 to 45 °C | |
| Terminal type | M6 | |
| Mounting | Rack-mount (wall-mount compatible) | Rack-mount |
| Physical | ||
| Dimensions D×W×H (mm) | 452×440×133 | 592×440×223 |
| Weight (net, ref., kg) | 45 | 100 |
Use the LR electrical limits as the starting point for system design. Confirm the AC supply where applicable, battery voltage, PV string limits and equipment connected to the output. Optional functions must be specified with the order.
Check the battery and charging requirements for the selected LR model. Match permitted charge and discharge current, charging profile and any supported BMS protocol. A matching connector or nominal voltage alone does not confirm compatibility. For a battery-free or DC-only product, use only the interfaces listed in its model table.
For a LR quotation, send the exact model, quantity, destination market, electrical requirements and expected operating duty. Identify any branding, packaging or documentation requirements separately so the supplied configuration is clear.
The table describes one published model revision. Confirm the current supply configuration before ordering.
Before You Order
Use the LR electrical limits as the starting point for system design. Confirm the AC supply where applicable, battery voltage, PV string limits and equipment connected to the output. Optional functions must be specified with the order.
Electrical Match
Check the battery and charging requirements for the selected LR model. Match permitted charge and discharge current, charging profile and any supported BMS protocol. A matching connector or nominal voltage alone does not confirm compatibility. For a battery-free or DC-only product, use only the interfaces listed in its model table.
Installation Plan
Install the LR product within the temperature, ventilation and enclosure conditions stated in its manual. Specify cable sizes, isolation and protection through a qualified installation design. Product dimensions and clearances should be checked before cabinet or mounting work.
Supply Configuration
LR Series — Selection and Application
The LR series belongs to the lifepo4 storage batteries range. Review the exact model in the specification table rather than selecting on the series name alone.
Parameter | 5120WH | 11776WH Basic parameters
Model selection
For LR, first identify the required electrical interface and continuous load.
Parameter | 5120WH | 11776WH Basic parameters
Operating features
Parameter | 5120WH | 11776WH
Basic parameters
Cell chemistry | LiFePO4
Max. continuous discharge current | 100A | 200A
Rated voltage | 51.2 VDC
System integration
Use the LR electrical limits as the starting point for system design. Confirm the AC supply where applicable, battery voltage, PV string limits and equipment connected to the output. Optional functions must be specified with the order.
Battery and charging
Check the battery and charging requirements for the selected LR model. Match permitted charge and discharge current, charging profile and any supported BMS protocol. A matching connector or nominal voltage alone does not confirm compatibility. For a battery-free or DC-only product, use only the interfaces listed in its model table.
Installation planning
Install the LR product within the temperature, ventilation and enclosure conditions stated in its manual. Specify cable sizes, isolation and protection through a qualified installation design. Product dimensions and clearances should be checked before cabinet or mounting work.
Monitoring and interfaces
Check which monitoring ports and communication options are included on the selected LR model. Confirm accessory hardware, protocol and firmware before relying on remote monitoring, battery communication or expansion.
Frequently asked questions
Which LR model should I choose? Start with the model table and the loads or battery system, then confirm the final configuration before ordering.
Are all optional functions included? No. Availability depends on the model, hardware and agreed supply specification.
Can I combine data from different catalogues? Use one matching model and revision. Confirm any differing values with the supplier.
Discuss your requirements