PA Series MPPT Controller
PA Series MPPT Solar Charge Controller 30/60 A
Parameter | PA30210 | PA60415
Rated system voltage | 12/24 V auto-sensing or fixed setting | 12/24/48 V auto-sensing or fixed setting
Controller operating voltage range | 9-32 V | 10-64 V
The PA series belongs to the mppt solar charge controllers range. Review the exact model in the specification table rather than selecting on the series name alone.
Parameter | PA30210 | PA60415 Rated system voltage | 12/24 V auto-sensing or fixed setting | 12/24/48 V auto-sensing or fixed setting
Structural Features
Key features of the PA platform:
- Parameter | PA30210 | PA60415
- Rated system voltage | 12/24 V auto-sensing or fixed setting | 12/24/48 V auto-sensing or fixed setting
- Controller operating voltage range | 9-32 V | 10-64 V
- Applicable battery types | Custom / sealed / flooded / gel / lithium
- Static loss | 0.7-1.2 W
Product Advantages
Parameter | PA30210 | PA60415
Rated system voltage | 12/24 V auto-sensing or fixed setting | 12/24/48 V auto-sensing or fixed setting
Controller operating voltage range | 9-32 V | 10-64 V
Applicable battery types | Custom / sealed / flooded / gel / lithium
Static loss | 0.7-1.2 W
For a PA quotation, send the exact model, quantity, destination market, electrical requirements and expected operating duty. Identify any branding, packaging or documentation requirements separately so the supplied configuration is clear.
Technical Parameters
| Parameter | PA30210 | PA60415 |
|---|---|---|
| General | ||
| Rated system voltage | 12/24 V auto-sensing or fixed setting | 12/24/48 V auto-sensing or fixed setting |
| Controller operating voltage range | 9-32 V | 10-64 V |
| Applicable battery types | Custom / sealed / flooded / gel / lithium | |
| Static loss | 0.7-1.2 W | |
| Input characteristics | ||
| Rated charging power | 400 W @12 V | 800 W @12 V |
| Rated charging power | 800 W @24 V | 1600 W @24 V |
| Rated charging power | — | 2400 W @36 V |
| Rated charging power | — | 3200 W @48 V |
| Max. PV module open-circuit voltage | 100Vdc | 150Vdc |
| PV input operating voltage range | 18-100 VDC @12 V system | 18-150 VDC @12 V system |
| PV input operating voltage range | 36-100 VDC @24 V system | 36-150 VDC @24 V system |
| PV input operating voltage range | — | 50-150 VDC @36 V system |
| PV input operating voltage range | — | 64-150 VDC @48 V system |
| MPPT operating voltage range | 18-72 VDC @12 V system | 18-110 VDC @12 V system |
| MPPT operating voltage range | 36-72 VDC @24 V system | 36-110 VDC @24 V system |
| MPPT operating voltage range | — | 50-110 VDC @36 V system |
| MPPT operating voltage range | — | 64-110 VDC @48 V system |
| Charging characteristics | ||
| Rated charging current | 30A | 60A |
| Tracking efficiency | ≥99.9% | |
| Max. conversion efficiency | 85-98% (10-100% of rated power) | |
| Temperature compensation coefficient | -3 mV/°C/2 V | |
| DC load output characteristics | ||
| DC load output voltage | Same as battery voltage | |
| DC load rated output current | 20A | |
| USB output port | 5V/2A | |
| DC load output control mode | Manual on/off / light sensing / time scheduling modes | |
| Other properties | ||
| Protection functions | PV reverse-polarity, battery reverse-polarity, over-charge/over-discharge, over-temperature, input power limiting, input over-voltage and load over-current protection | |
| Cooling method | Natural cooling | |
| Communication | RS485/RS232 | |
| Protection rating | IP32 | |
| Display | High-definition segment LCD | |
| BMS communication | None | Yes |
| Environment | ||
| Operating temperature range | -20 to +50 °C | |
| Storage temperature range | -30 to +70 °C | |
| Relative humidity range | 0-90% RH | |
| Mechanical | ||
| Dimensions | 220×215×83mm | 310×215×83mm |
| Recommended wiring | 11AWG/4mm² | 7AWG/10mm² |
Use the PA electrical limits as the starting point for system design. Confirm the AC supply where applicable, battery voltage, PV string limits and equipment connected to the output. Optional functions must be specified with the order.
Check the battery and charging requirements for the selected PA model. Match permitted charge and discharge current, charging profile and any supported BMS protocol. A matching connector or nominal voltage alone does not confirm compatibility. For a battery-free or DC-only product, use only the interfaces listed in its model table.
For a PA quotation, send the exact model, quantity, destination market, electrical requirements and expected operating duty. Identify any branding, packaging or documentation requirements separately so the supplied configuration is clear.
The table describes one published model revision. Confirm the current supply configuration before ordering.
Before You Order
Use the PA electrical limits as the starting point for system design. Confirm the AC supply where applicable, battery voltage, PV string limits and equipment connected to the output. Optional functions must be specified with the order.
Electrical Match
Check the battery and charging requirements for the selected PA model. Match permitted charge and discharge current, charging profile and any supported BMS protocol. A matching connector or nominal voltage alone does not confirm compatibility. For a battery-free or DC-only product, use only the interfaces listed in its model table.
Installation Plan
Install the PA product within the temperature, ventilation and enclosure conditions stated in its manual. Specify cable sizes, isolation and protection through a qualified installation design. Product dimensions and clearances should be checked before cabinet or mounting work.
Supply Configuration
PA Series — Selection and Application
The PA series belongs to the mppt solar charge controllers range. Review the exact model in the specification table rather than selecting on the series name alone.
Parameter | PA30210 | PA60415 Rated system voltage | 12/24 V auto-sensing or fixed setting | 12/24/48 V auto-sensing or fixed setting
Model selection
For PA, first identify the required electrical interface and continuous load.
Parameter | PA30210 | PA60415 Rated system voltage | 12/24 V auto-sensing or fixed setting | 12/24/48 V auto-sensing or fixed setting
Operating features
Parameter | PA30210 | PA60415
Rated system voltage | 12/24 V auto-sensing or fixed setting | 12/24/48 V auto-sensing or fixed setting
Controller operating voltage range | 9-32 V | 10-64 V
Applicable battery types | Custom / sealed / flooded / gel / lithium
Static loss | 0.7-1.2 W
System integration
Use the PA electrical limits as the starting point for system design. Confirm the AC supply where applicable, battery voltage, PV string limits and equipment connected to the output. Optional functions must be specified with the order.
Battery and charging
Check the battery and charging requirements for the selected PA model. Match permitted charge and discharge current, charging profile and any supported BMS protocol. A matching connector or nominal voltage alone does not confirm compatibility. For a battery-free or DC-only product, use only the interfaces listed in its model table.
Installation planning
Install the PA product within the temperature, ventilation and enclosure conditions stated in its manual. Specify cable sizes, isolation and protection through a qualified installation design. Product dimensions and clearances should be checked before cabinet or mounting work.
Monitoring and interfaces
Check which monitoring ports and communication options are included on the selected PA model. Confirm accessory hardware, protocol and firmware before relying on remote monitoring, battery communication or expansion.
Frequently asked questions
Which PA model should I choose? Start with the model table and the loads or battery system, then confirm the final configuration before ordering.
Are all optional functions included? No. Availability depends on the model, hardware and agreed supply specification.
Can I combine data from different catalogues? Use one matching model and revision. Confirm any differing values with the supplier.
Discuss your requirements
Contact Techfine Group with your PA requirements. Include the model and the application so the electrical configuration and supporting documents can be checked.